Bella

2 Rooms
•
2 Bathrooms
•
from
107.460
€
119.4m²
•
2 Rooms

Bella

119.4 m²

Bella is a 119 m² single-level home defined by a clear and logical layout. At its centre, an open living, dining and kitchen area rises to a high ceiling, with large glazing that brings in natural light and a strong sense of openness. The bedrooms are positioned in a separate zone, maintaining a clear distinction between shared and private spaces.

Three bedrooms, a sauna with washing area, a technical room and integrated storage form a complete and well-balanced solution. Circulation is straightforward and intuitive, with each function placed deliberately. Bella is shaped by a calm spatial logic where every space has a defined role and purpose.

Floor plan
Adjustable
Building height
5.8m
Ceiling height
2.6 m
Energy class
A
Construction time
10 weeks

Floor Plan

The layout shown represents the standard configuration. Modifications are possible to better suit your site and individual needs.
Floorplan

Finished by us or completed by you

We build your timber frame house for long-term durability. You choose whether to finish the interior yourself or receive a fully completed home.
Semi-Finished
·
from 107.460
Completed exterior and prepared interior, allowing you to finish the home to your own specifications.
Full Turnkey
·
from 190.000
Fully finished home with all technical systems installed, delivered ready for occupancy.

Planning your timber frame house?
Let’s discuss the right solution for your project.

Follow us on social media to stay up to date with our latest houses, projects and news.

Choose language

Request a Quote

Leave your details below and we will prepare a personalised quotation.
Contact info
Location
House Selection
Additional informantion
Youre Message (optional)

Semi-Finished

Completed exterior and prepared interior, allowing you to finish the home to your own specifications.
STRUCTURE
Factory-built timber frame system
Prefabricated structural elements produced indoors under controlled conditions. Designed for structural stability, airtightness and long-term performance in Northern climates.
Load-bearing timber structure
Strength-graded structural timber compliant with EU construction standards. Engineered for durability and dimensional stability.
Insulated wall and roof elements
Multi-layer construction designed to meet modern energy performance requirements and provide a stable indoor climate.
Airtight membrane system
Interior airtight layer with controlled vapor diffusion to protect the structure and support energy efficiency.
EXTERIOR FINISHES
Finished facade system
Factory-prepared facade cladding system installed according to the selected design specification.
Roof system completed
Fully installed roofing structure with waterproof membrane and drainage solution according to project design.
Installed windows and exterior doors
Energy-efficient windows with multi-layer glazing installed and sealed.
Integrated rainwater drainage system
Gutters and downpipes installed and prepared for site connection.
INTERIOR PREPARATION
Interior partition walls installed
Internal walls assembled and covered with gypsum boards.
Ceilings covered with gypsum boards
Ceiling structures installed and ready for finishing.
Concrete subfloor
Floor base prepared and ready for installation of final floor coverings.
Wet areas structurally prepared
Bathrooms prepared with installed plumbing connections and structural waterproof base layers where specified.
TECHNICAL SYSTEMS
Electrical system installed
Wiring completed and distribution board installed. Final switches and fixtures may require finishing depending on project scope.
Plumbing system installed
Water and sewage systems installed and pressure-tested.
Ventilation system installed
Mechanical ventilation system installed and prepared for commissioning.
Heating system installed
Heating solution installed according to project specification.
Technical room prepared
Primary systems installed and ready for utility connection.
INTERIOR COMPLETION RESPONSIBILITY
Under the Semi-Finished option, the client completes:
Final wall finishing and painting
Floor coverings
Interior doors and trims
Bathroom tiling and sanitary equipment installation
Lighting fixtures
Kitchen and built-in furniture
This option provides flexibility in material choice, budgeting and interior design execution.
NOT INCLUDED (STANDARD SCOPE)
Kitchen furniture and appliances
Built-in wardrobes or custom furniture
Final floor coverings
Interior painting
Sanitary fixtures installation
Decorative lighting fixtures
Foundation works (unless separately agreed)
Utility connection fees
WARRANTIES
Structural warranty according to EU regulations
Manufacturer warranties for installed technical systems
Standard construction warranty period
DISCLAIMER
Technical performance values depend on project size, orientation, climate conditions and final interior solutions chosen by the client.

Full turnkey

Fully completed house delivered ready for occupancy.
STRUCTURE
Factory-built timber frame system
Prefabricated structural elements produced indoors under controlled conditions. Designed for structural stability, airtightness and long-term performance in Northern climates.
Load-bearing timber structure (C24 grade)
Strength-graded structural timber compliant with EU construction standards. Engineered for durability and dimensional stability.
Insulated wall and roof elements
Multi-layer construction designed to meet modern energy efficiency requirements and ensure stable indoor climate throughout the year.
Airtight membrane system
Interior airtight layer with controlled vapor diffusion to protect the structure and improve energy performance.
EXTERIOR FINISHES
Finished facade system
Factory-prepared facade cladding system installed according to the selected design specification.
Roof system completed
Fully installed roofing structure with waterproof membrane and drainage solution according to project design.
Installed windows and exterior doors
Energy-efficient windows with multi-layer glazing. Exterior doors installed and sealed.
Integrated rainwater drainage system
Gutters and downpipes installed and connected to exterior drainage points.
COMPLETE INTERIOR FINISHES
Painted walls and ceilings
Interior wall and ceiling surfaces finished, painted and ready for use.
Installed floor coverings
Standard parquet or floor finish installed according to agreed material category.
Interior doors and trims installed
Interior doors, frames and finishing trims installed.
Installed skirting boards
Matching skirting boards installed throughout finished areas.
BATHROOM FINISHES
Tiled walls and floors
Wet areas fully waterproofed and tiled according to standard specification.
Installed sanitary equipment
WC units, shower or bath installed and connected.
Waterproofing system certified
Wet areas constructed according to EU-compliant waterproofing standards.
TECHNICAL SYSTEMS
Electrical system completed and tested
Distribution board installed. Wiring, sockets and switches completed according to project.
Plumbing system operational
Water and sewage systems installed and pressure-tested.
Ventilation system commissioned
Mechanical ventilation installed and tested.
Heating system installed and adjusted
Heating solution installed according to project specification.
Technical room completed
All primary systems installed and ready for utility connection.
INTERIOR SELECTION PROCESS
Following contract signing, clients selecting the Full Turnkey option receive:

- Material selection meeting:
Selection of standard-category parquet, tiles, interior doors and wall finishes within agreed budget range.

- 2-hour interior design consultation:
Guidance session with interior consultant to align materials and finishes with overall design concept.
NOT INCLUDED (STANDARD SCOPE)
Kitchen furniture and appliances
Built-in wardrobes or custom furniture
Decorative lighting fixtures
Loose furniture
Landscaping works
Foundation works (unless separately agreed)
Utility connection fees
WARRANTIES
Structural warranty according to EU regulations
Technical systems warranty according to manufacturer terms
Standard construction warranty period
Manufacturer warranties apply to installed components
DISCLAIMER
Technical performance values depend on project size, orientation, climate conditions and usage patterns. Final specifications are defined in the signed project documentation.